Daya Cergas

Our Products

Select Category
product_type
66a4a368561bc
0
1
Loading....

Airvo™ Neb

Nebulize without interruption to therapy

The Airvo Neb has been engineered with convenience in mind. As the adapter is part of the water chamber there’s, no need to hold it in place during treatment.

Compatible with 22mm vibrating mesh nebulizers.

Built with advanced nebulizer technology

Designed for use with the latest technology; vibrating mesh nebulizers and the smooth inner surfaces of AirSpiral tubing.

Designed for maximum delivery efficiency

Independent testing* of the Airvo Neb demonstrated an emitted dose as high as 39%†

*Testing was undertaken in cooperation with Aerogen.
†This result was found using an Optiflow (size medium) cannula at 10 L/min. At 30 L/min and 60 L/min the emitted dose was 37% and at 12% respectively.

The best of Airvo 2 technology in one kit

Compatible with Optiflow™ Nasal Interfaces (2 to 60 L/min) Included in the nebulizer kit:

1. Airvo Neb port and plug
2. AirSpiral™ heated breathing tube
3. MR290 auto-fill humidification chamber

4. Vibrating mesh nebulizer*

*The vibrating mesh nebulizer depicted here is the Aerogen Solo (sold separately)

Product Codes

Part No
Description
Quantity
900PT562
AirSpiral tube and chamber kit including Airvo Neb Adapter (Aerogen® Solo nebulizer not included)
10/box

Resource download list

AirSpiral™ tube for less condensate

The AirSpiral heated breathing tube produces up to 93% less condensate

Advanced two-spiral design

The AirSpiral heated breathing tube for Airvo 2 utilizes an advanced two-spiral design to help protect against condensate.

We’ve all seen it happen before. When warm, humid gas touches anything even a fraction of a degree colder than itself (i.e. dew point), it cools and generates condensate. We see it often in conventional breathing tubes made of thin, dense plastic: their surfaces are easily cooled by the outside air, resulting in unpleasant “rain-out”.

Tubing clip

The molded clip attaches to clothes or bedding to allow positioning of the
tube during use.

Integrated temperature sensor

No external probes, cables or adaptors required.

Ergonomically designed

Molded grips at both ends of the tube assist connection and disconnection.

An Airvo 2 heated breathing tube that connects to both Optiflow™ and Optiflow Junior Interfaces.

Product Codes

Part No
Description
Quantity
900PT561
AirSpiral tube and chamber kit for Airvo 2
10/box

Resource download list

Adult Circuits for F&P 850 System

Fisher & Paykel Healthcare offers a range of breathing circuit solutions for adults.

Designed to minimize condensation and maintain humidity delivery between the MR850 Humidifier and the patient interface.

F&P Evaqua 2

Less condensate, without compromise.

The F&P Evaqua 2™ circuit incorporates MicroCell™ technology in the inspiratory limb and Evaqua™ technology in the expiratory limb. The result is an easy-to-use circuit with less condensation, which promotes a closed system and reduced clinician intervention.

Other RT-series Breathing Circuits

Fisher & Paykel Healthcare offer a range of RT-Series breathing circuits specifically designed for the F&P 850 System. These circuits cater to therapies across the adult respiratory care continuum.

Product Codes

Evaqua 2 adult breathing circuits

Part No
Description
Quantity
RT380
Dual limb adult breathing circuit kit with Evaqua 2 technology
10/box
RT385
Dual Limb Adult Breathing Circuit Kit with Evaqua 2 Technology and Pressure Line
10/box

Conventional adult breathing circuits

Part No
Description
Quantity
RT319
Single limb adult breathing circuit kit with low resistance to flow inspiratory limb, flexible extension, exhalation port, inspiratory filter and pressure line
10/box
RT219
Single limb adult breathing circuit kit with low resistance to flow inspiratory limb, flexible extension, exhalation port and pressure line
10/box
RT202
Adult single limb heated inspiratory and MR290 chamber kit
10/box
RT100
Dual limb adult breathing circuit (excl. chamber)
10/box
RT105
Dual limb adult breathing circuit (excl. chamber) with expiratory water-trap
10/box
RT200
Dual limb adult breathing circuit kit
10/box
RT204
Dual limb adult breathing circuit kit with pressure line
10/box
RT205
Dual limb adult breathing circuit kit with expiratory water-trap
10/box
RT206
Dual limb adult breathing circuit kit with expiratory water-trap and pressure line
10/box

Infant Circuits for F&P 850 System

Fisher & Paykel Healthcare offers a range of breathing circuit solutions for infants.

Designed to minimize condensation and maintain humidity delivery between the MR850 Humidifier and the patient interface.

F&P Evaqua 2

Less condensate, without compromise.

The F&P Evaqua 2™ circuit incorporates MicroCell™ technology in the inspiratory limb and Evaqua™ technology in the expiratory limb. The result is an easy-to-use circuit with less condensation, which promotes a closed system and reduced clinician intervention.

Other RT-series Breathing Circuits

Fisher & Paykel Healthcare offer a range of RT-Series breathing circuits specifically designed for the F&P 850 System. These circuits cater to therapies across the infant respiratory care continuum.

Product Codes

Evaqua 2 infant breathing circuits

Part No
Description
Quantity
RT265
Dual heated infant circuit kit with Evaqua 2 technology and MR290 Auto-fill Chamber (flow > 4 L/min)
10/box
RT266
Dual heated infant circuit kit with Evaqua 2 technology and MR290 Auto-fill Chamber (flow 0.3-4 L/min
10/box
RT267
Dual heated infant circuit kit with Evaqua 2 technology and MR290 Auto-fill Chamber for SLE2000 Series Ventilators
10/box
RT268
Dual heated infant circuit kit with Evaqua 2 technology and MR290 Auto-fill Chamber for SLE5000 Series Ventilators
10/box

Conventional infant breathing circuits

Part No
Description
Quantity
RT224
Infant Continuous Flow Circuit (>4L/min) Single Heated with MR290 Autofeed Chamber
10/box
RT225
Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber (flow > 4 L/min)
10/box
RT226
Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber (flow 0.3 - 4 L/min)
10/box
RT227
Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber for SLE2000 ventilators
10/box
RT228
Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber for SLE5000 ventilators
10/box
RT329
Single limb infant breathing circuit kit with pressure relief valve
10/box