Adult Circuits for F&P 850 System

Fisher & Paykel Healthcare offers a range of breathing circuit solutions for adults.

Designed to minimize condensation and maintain humidity delivery between the MR850 Humidifier and the patient interface.

F&P Evaqua 2

Less condensate, without compromise.

The F&P Evaqua 2™ circuit incorporates MicroCell™ technology in the inspiratory limb and Evaqua™ technology in the expiratory limb. The result is an easy-to-use circuit with less condensation, which promotes a closed system and reduced clinician intervention.

Other RT-series Breathing Circuits

Fisher & Paykel Healthcare offer a range of RT-Series breathing circuits specifically designed for the F&P 850 System. These circuits cater to therapies across the adult respiratory care continuum.

Product Codes

Evaqua 2 adult breathing circuits

Part No
Description
Quantity
RT380
Dual limb adult breathing circuit kit with Evaqua 2 technology
10/box
RT385
Dual Limb Adult Breathing Circuit Kit with Evaqua 2 Technology and Pressure Line
10/box

Conventional adult breathing circuits

Part No
Description
Quantity
RT319
Single limb adult breathing circuit kit with low resistance to flow inspiratory limb, flexible extension, exhalation port, inspiratory filter and pressure line
10/box
RT219
Single limb adult breathing circuit kit with low resistance to flow inspiratory limb, flexible extension, exhalation port and pressure line
10/box
RT202
Adult single limb heated inspiratory and MR290 chamber kit
10/box
RT100
Dual limb adult breathing circuit (excl. chamber)
10/box
RT105
Dual limb adult breathing circuit (excl. chamber) with expiratory water-trap
10/box
RT200
Dual limb adult breathing circuit kit
10/box
RT204
Dual limb adult breathing circuit kit with pressure line
10/box
RT205
Dual limb adult breathing circuit kit with expiratory water-trap
10/box
RT206
Dual limb adult breathing circuit kit with expiratory water-trap and pressure line
10/box

Infant Circuits for F&P 850 System

Fisher & Paykel Healthcare offers a range of breathing circuit solutions for infants.

Designed to minimize condensation and maintain humidity delivery between the MR850 Humidifier and the patient interface.

F&P Evaqua 2

Less condensate, without compromise.

The F&P Evaqua 2™ circuit incorporates MicroCell™ technology in the inspiratory limb and Evaqua™ technology in the expiratory limb. The result is an easy-to-use circuit with less condensation, which promotes a closed system and reduced clinician intervention.

Other RT-series Breathing Circuits

Fisher & Paykel Healthcare offer a range of RT-Series breathing circuits specifically designed for the F&P 850 System. These circuits cater to therapies across the infant respiratory care continuum.

Product Codes

Evaqua 2 infant breathing circuits

Part No
Description
Quantity
RT265
Dual heated infant circuit kit with Evaqua 2 technology and MR290 Auto-fill Chamber (flow > 4 L/min)
10/box
RT266
Dual heated infant circuit kit with Evaqua 2 technology and MR290 Auto-fill Chamber (flow 0.3-4 L/min
10/box
RT267
Dual heated infant circuit kit with Evaqua 2 technology and MR290 Auto-fill Chamber for SLE2000 Series Ventilators
10/box
RT268
Dual heated infant circuit kit with Evaqua 2 technology and MR290 Auto-fill Chamber for SLE5000 Series Ventilators
10/box

Conventional infant breathing circuits

Part No
Description
Quantity
RT224
Infant Continuous Flow Circuit (>4L/min) Single Heated with MR290 Autofeed Chamber
10/box
RT225
Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber (flow > 4 L/min)
10/box
RT226
Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber (flow 0.3 - 4 L/min)
10/box
RT227
Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber for SLE2000 ventilators
10/box
RT228
Dual limb infant breathing circuit (excl. chamber) with expiratory water-trap and MR290 Auto-fill Chamber for SLE5000 ventilators
10/box
RT329
Single limb infant breathing circuit kit with pressure relief valve
10/box

Heater-Wire

Adapter

The Heater Wire Adapter is designed for making electrical connection between the Fisher & Paykel Healthcare MR850 and Fisher & Paykel Healthcare heated breathing circuits.

The heater-wire adapter for the F&P 850 System powers the inspiratory and expiratory limbs, heating the water vapor inside to remain above its dew point temperature. This heating reduces condensation from forming in the breathing circuit.

Product Codes

Part No
Description
Quantity
900MR805
Heater-wire adapter for RT-series dual heated breathing circuits
1/each
900MR806
Heater-wire adapter for RT-series inspiratory heated breathing circuits
1/each

Temperature and

Flow Probe

The temperature and flow probe provides feedback to the MR850 heater base for power adjustment.

It is designed for measuring gas temperature and flow with Fisher & Paykel Healthcare MR850 and HC550 Humidifiers and Fisher & Paykel Healthcare Breathing Circuits.

Product Codes

Part No
Description
Quantity
900MR869
Temperature and flow probe adapter for 1.5 m (60") long RT-series breathing circuits
1/each
900MR868
Temperature and flow probe adapter for 1.1 m (44") long RT-series breathing circuits
1/each
900MR863
Temperature and flow probe adapter for 0.7 m (28") long RT-series breathing circuits
1/each
900MR861
Temperature and flow probe adapter for 1.8 m (72") long RT-series breathing circuits
1/each
900MR860
Temperature and flow probe adapter for 1.3 m (52") long RT-series breathing circuits
1/each

FlexiTrunk™ Interface

The Fisher & Paykel Healthcare FlexiTrunk nasal CPAP interface is an integrated solution that includes all the necessary components for delivering CPAP, such as nasal masks, nasal prongs, bonnet, and headgear.

FlexiTrunk Interface features

All the components of FlexiTrunk Interface (nasal masks, nasal prongs, bonnet, and headgear) are designed to fit and work together. With 11 nasal prongs, 4 nasal masks, and 3 nasal tubing lengths, FlexiTrunk Interface offers a wide size range to provide the correct fit for a variety of patients.

By offering both a nasal mask and nasal prongs interface, FlexiTrunk Interface allows healthcare professionals to cycle between interface types during CPAP therapy.

FlexiTrunk Interface’s mid-line design and the flexible tubing help to facilitate multiple caring positions including prone and supine, while the mask range is designed to minimize the force needed to create a seal.

Moisture-wicking technology is built into the interface to help minimize condensate build-up. The large-diameter tubing reduces resistance to flow.

How to fit the F&P FlexiTrunk™ Interface

A short instructional video for healthcare professionals demonstrating how to fit the Fisher & Paykel Healthcare FlexiTrunk™ interface.

Product Codes

FlexiTrunk™ nasal tubing

Part No
Description
Quantity
BC190-05
FlexiTrunk™ nasal tubing (50mm)
5/box
BC191-05
FlexiTrunk™ nasal tubing (70mm)
5/box
BC192-05
FlexiTrunk™ nasal tubing (100mm)
5/box

Nasal prongs and nasal masks

Part No
Description
Quantity
BC3020-10
Nasal prongs (3.0mm nare diameter / 2.0mm septal width)
10/box
BC3520-10
Nasal prongs (3.5mm nare diameter / 2.0mm septal width)
10/box
BC4030-10
Nasal prongs (4.0mm nare diameter / 3.0mm septal width)
10/box
BC4540-10
Nasal prongs (4.5mm nare diameter / 4.0mm septal width)
10/box
BC5040-10
Nasal prongs (5.0mm nare diameter / 4.0mm septal width)
10/box
BC5050-10
Nasal prongs (5.0mm nare diameter / 5.0mm septal width)
10/box
BC5550-10
Nasal prongs (5.5mm nare diameter / 5.0mm septal width)
10/box
BC5560-10
Nasal prongs (5.5mm nare diameter / 6.0mm septal width)
10/box
BC6060-10
Nasal prongs (6.0mm nare diameter / 6.0mm septal width)
10/box
BC6070-10
Nasal prongs (6.0mm nare diameter / 7.0mm septal width)
10/box
BC6570-10
Nasal prongs (6.5mm nare diameter / 7.0mm septal width)
10/box
BC800-10
Nasal mask – small
10/box
BC801-10
Nasal mask – medium
10/box
BC802-10
Nasal mask – large
10/box
BC803-10
Nasal mask – extra large
10/box

Infant bonnets, headgear and chinstraps

Part No
Description
Quantity
BC300-05
Bonnet (17-22cm)
5/box
BC303-05
Bonnet (22-25cm)
5/box
BC306-05
Bonnet (25-29cm)
5/box
BC309-05
Bonnet (29-36cm)
5/box
BC325-05
Headgear (29-36cm)
5/box
BC328-05
Headgear (35-40cm)
5/box
BC331-05
Headgear (40-45cm)
5/box
BC351-10
Chinstrap (20-26cm)
10/box
BC353-10
Chinstrap (26-32cm)
10/box
BC355-10
Chinstrap (32-38cm)
10/box
BC357-10
Chinstrap (38-44cm)
10/box

Bubble CPAP System

Continuous positive airway pressure (CPAP) therapy delivers a heated and humidified blend of air and oxygen while at the same time generating a continuous distending pressure throughout the respiratory cycle. Fisher & Paykel Healthcare offers a system including circuits, a pressure relief manifold, and Bubble CPAP generator.

Bubble CPAP generator features

The Fisher & Paykel Healthcare Bubble CPAP generator is designed to provide consistent pressure through an auto-leveling feature. This design moves excess liquid into a separate chamber from the main pressure-generating section, automatically ensuring that the set pressure does not change with liquid build-up.

The bubble generator includes an overflow container that can be detached to remove excess water from the system, without disrupting delivery therapy.

How to set up the F&P Bubble CPAP System

A short instructional video for healthcare professionals outlining how to set up the Bubble CPAP delivery system with the F&P MR850 humidifier.

Product Codes

Part No
Description
Quantity
BC151-10
Infant Bubble CPAP system including inspiratory heated breathing circuit with autofeed chamber, pressure relief manifold & Bubble CPAP generator (connect to T-bar interface)
10/box
BC161-10
Infant Bubble CPAP system including inspiratory heated breathing circuit with autofeed chamber, pressure relief manifold & Bubble CPAP generator (connects to F&P interface)
10/box
BC171-10
Infant Bubble CPAP system including inspiratory heated breathing circuit with autofeed chamber, pressure manifold with dryline, pressure line and CPAP generator (connects to Flow Driver)
10/box

Resuscitation Masks for Neopuff™

The Fisher & Paykel Healthcare resuscitation masks for neonates and infants are available in five different sizes to fit a range of patients.

International guidelines recommend that an appropriately sized infant face mask should cover the mouth and nose but not the eyes, and should not overlap the chin. Careful consideration needs to be given to mask size, fit and hold as a good seal with minimized leak is important for establishing effective ventilation.

Resuscitation mask product features

The resuscitation mask range by Fisher & Paykel Healthcare includes masks of 35mm and 42 mm diameter, which are amongst the smallest masks currently available on the market.

Research shows that 35-millimeter-diameter masks are most suitable for infants younger than 29 weeks’ gestational age, while masks with a 42-millimeter diameter are recommended for infants between 27 and 33 weeks’ gestational age.

Fisher & Paykel Healthcare’s resuscitation masks can be used with a self-inflating bag, a flow-inflating bag or a T-piece circuit. The infant masks are designed to be soft and pliable, with a transparent surface that allows breath condensate to be observed.

Product Codes

Part No
Description
Quantity
RD803-10
X-Small Resuscitation Mask (35mm diameter)
10/box
RD804-10
Small Resuscitation Mask (42mm diameter)
10/box
RD805-10
Medium Resuscitation Mask (50mm diameter)
10/box
RD806-10
Large Resuscitation Mask (60mm diameter)
10/box
RD807-10
X-Large Resuscitation Mask (72mm diameter)
10/box

T-piece Circuits for Neopuff™

Fisher & Paykel Healthcare offers three types of T-piece circuits: classic, ergonomic and humidified

All of these circuits can be connected to a mask or endotracheal tube, and they all have positive end-expiratory pressure (PEEP) valves for adjusting pressure. 

Classic

Ergonomic

Humidified

T-piece circuit product features

The classic T-piece circuit has a standard T-piece to connect to a mask or endotracheal tube, along with a PEEP valve to adjust pressure.

In addition to the features of the classic T-piece circuit, the ergonomic T-piece circuit includes a duckbill port for suctioning and delivering surfactant during resuscitation. The T-piece also has a blue protective cover that can be used to set and check pressures. The angled orientation of the PEEP valve has been designed to allow operators to use a more ergonomic hand position.

With spiral heater-wire throughout the circuit tubing, Fisher & Paykel Healthcare’s heated and humidified T-piece circuit is designed to deliver warm, humidified gas using the Fisher & Paykel Healthcare MR850 humidifier and the MR290 chamber. Resuscitation with heated and humidified gas is associated with a higher rate of normothermia (rectal temperature between 36.5°C and 37.5 °C) on admission to the neonatal intensive care unit (NICU).

Product Codes

Part No
Description
Quantity
RD1300-10
Single use Ergonomic T-piece circuit
10/box
900RD010
Single Use Classic T-Piece Circuit
10/box
900RD110
Single Use Humidified T-Piece Circuit
10/box

Neopuff™

The Neopuff is a T-piece resuscitator designed by Fisher & Paykel Healthcare to deliver controlled, consistent, and precise pressures – independent of operator experience.

It can provide assisted respiratory breaths to neonates and infants (up to 10 kg) in the delivery room or neonatal intensive care unit (NICU).

International neonatal resuscitation guidelines recommend the use of a T-piece resuscitator

Compared to self-inflating and flow-inflating bags, T-piece resuscitators like the Neopuff deliver a more controlled and consistent peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP),6,7 which helps to protect the newborn’s lungs.

Pressure measurements obtained from a resuscitation simulator while a self-inflating bag and a F&P Neopuff were used by a qualified resuscitator.

Neopuff™ product features

The Neopuff resuscitator can deliver oxygen levels ranging from 21% through to 100%, from a flow meter or blender.

The resuscitator has a PIP control, as well as a maximum pressure relief valve that prevents the accidental delivery of excessively high pressures.

The Neopuff resuscitator features an accurate, easy-to-read, medical quality manometer, and can be mounted on a pole, rail, wall, infant warmer, or incubator.

How to set up and use the Neopuff™ Resuscitator

A short instructional video for healthcare professionals outlining how to set up and use the Fisher & Paykel Neopuff™ Infant Resuscitator.

Product Codes

Neopuff Infant T-Piece Resuscitator

Part No
Description
RD900
F&P Neopuff Infant T-Piece Resuscitator

Neopuff Infant T-Piece Resuscitator Accessories

Part No
Description
Quantity
RD020-01
Silicone test lung (not autoclavable)
1/each
900RD008
Neopuff Gas Supply Line 31CM
10/box
900RD009
Neopff Gas Supply Line 2.1M
10/box
900RD101
Gas Inlet Adaptor
10/box

MR290 Auto-Fill Humidification Chamber

  • Suitable for all MR-series humidifiers
  • Automatically refills
  • Dual-float mechanism for added safety to prevent the chamber overfilling
  • Consistent compressible volume allows for consistent delivery of the prescribed waveform

Product Codes

Part No
Description
Quantity
MR290V
Auto-fill humidification chamber
40/box
MR290HFV
Auto-fill humidification chamber for high frequency ventilation
40/box

MR250 Manual-Fill Adult Chamber

  • Designed for adult patients
  • Allows for manual filling

Product Codes

Part No
Description
Quantity
MR250
MR250 manual-fill chamber
40/box

MR225 Manual-Fill Infant Chamber

  • Designed for neonatal and pediatric patients
  • Low compliance, compressible volume and resistance to flow – optimal for high frequency oscillators and CPAP generators

Product Codes

Part No
Description
Quantity
MR225
Manual-fill humidification chamber for neonate/pediatric
40/box

Optiflow+ tracheostomy interface

Humidified high flow therapy for tracheostomy patients

Evaqua™ technology

1. Designed to reduce the formation of condensation.

93% less condensate*

2. Connects to our AirSpiral™ breathing tube for 93% less condensate*

*compared with F&P Airvo™ 900PT501 breathing tube in internal Fisher & Paykel Healthcare testing.

Stable Easy to use

3. Re-designed sputum guard provides stability and ease of use.

Also available as a spare part.

Product Codes

Part No
Description
Quantity
OPT970
Optiflow+ Tracheostomy interface
20/box

Optiflow+ Nasal High Flow Interface

Comfort + Confidence for patients and clinicians

The leading-edge design of the Optiflow+ cannula originates from Fisher & Paykel Healthcare’s dedication to improve care and outcomes, giving clinicians confidence in the comfortable delivery of Nasal High Flow.

The unique concave base, together with the soft contured prongs, are deisgned to provide comfort to the septum on the face.

1.

Evaqua™ technology is designed to reduce the formation of mobile condensate.

2.

The three-way connector fits all F&P circuits, Airvo™ and F&P 850 systems.

3.

An adjustable head strap provides a secure, soft fit.

4.

The head strap clip removes the need for a lanyard.

5.

Soft cheek pads are designed to add stability and reduce pressure on the face.

6.

Contoured prongs for a softer fit.

Fitting guides and instructions

Learn how to effectively fit the Optiflow™+ nasal cannula by watching the instructional video.

Product Codes

Part No
Description
Quantity
OPT942
Optiflow+ Nasal Cannula (small)
20/box
OJR944
Optiflow+ Nasal Cannula (medium)
20/box
OPT946
Optiflow+ Nasal Cannula (large)
20/box

Optiflow™ Junior 2 Nasal Interface

The Fisher & Paykel Healthcare Optiflow Junior 2 Nasal Interface is a non-sealing nasal interface specifically designed for the flow requirements and anatomical features of neonates, infants, and children on nasal high flow (NHF) therapy. NHF offers a range of benefits compared to standard oxygen therapy, and there are several mechanisms of action associated with this treatment, including airway hydration and reduction of anatomical dead space.

Optiflow Junior 2 Nasal Interface features

Waveflex™ technology for prong stability and easier readjustment

The Optiflow Junior 2 cannula uses Waveflex technology to allow for natural facial movement when a patient’s cheeks are compressed. This improves prong stability in the nostrils.

Wide range of sizes and flow ranges

Optiflow Junior 2 offers a range of five cannula sizes with flow ranges from 0.5 to 25 L/min to provide respiratory support for even your smaller patients.

Wigglepads™ 2 allow for easy application and adjustment of the cannula

Wigglepads 2 retains the same technology as the original Wigglepads and applies it to unique shape of the Optiflow Junior 2 cannula.

Optiflow Junior 2 uses FlexiTube to minimize condensate build-up

The FlexiTube is made with a breathable material to reduce condensate build-up by allowing water vapor to diffuse through the membrane to the outside of the tubing.

Optiflow Junior 2 Nasal Interface Transition Kits

Optiflow Junior 2 Nasal Interface Ventilator Transition Kit

The Fisher & Paykel Healthcare Optiflow Junior 2 Nasal Interface Ventilator Transition Kit allows patients to receive NHF therapy for postextubation support – without changing the invasive circuit. The ability to keep the invasive circuit in place allows for easy trialing of NHF.

Sizes available: XS, S, M, L, XL

Optiflow Junior 2 Nasal Interface Blender Transition Kit

The Fisher & Paykel Healthcare Optiflow Junior 2 Nasal Interface Blender Transition Kit allows patients to receive NHF therapy as an alternative to prolonged continuous positive airway pressure (CPAP) therapy – without changing the CPAP circuit.

Sizes available: XS, S, M, L, XL

Optiflow Junior 2+ XXL Nasal Interface

Bridging the gap between the XL Optiflow Junior 2 nasal interface and the small-sized Optiflow+ nasal interface.

Product Features

The Optiflow Junior 2+ XXL Nasal Interface features larger tubing than the Optiflow Junior 2 to offer the potential for using higher flow rates of 1 to 50 L/min

WigglewiNG™

The F&P WigglewiNG can be used in conjunction with the Optiflow Junior 2 Nasal Interface and Optiflow Junior 2+ Nasal Interface range to stabilize a nasogastric (NG) tube to the patient, while maintaining the ability to remove or reposition the interface if necessary.

Easy

WigglewiNG is a ready-made solution that eases application and care associated with NG fixation once caregivers are familiar with its application.

Tidy

WigglewiNG offers an elegant solution that looks tidy on a patient’s face, and allows caregivers to interact with their child. With in-built WigglePadTM hook and loop, no additional tape is required.

Secure

WigglewiNG stays in place while repositioning the Optiflow Junior 2/2+ Nasal Interface range, offering a stable solution to NG fixation.

Product Codes

Optiflow™ Junior 2 Nasal Interface

Part No
Description
Quantity
OJR410
Optiflow Junior 2 Nasal Interface XS
20/box
OJR412
Optiflow Junior 2 Nasal Interface S
20/box
OJR414
Optiflow Junior 2 Nasal Interface M
20/box
OJR416
Optiflow Junior 2 Nasal Interface L
20/box
OJR418
Optiflow Junior 2 Nasal Interface XL
20/box

Optiflow Junior 2 Blender and Ventilator Transition Kits

Part No
Description
Quantity
OJR410VT
Optiflow Junior 2 Nasal Interface Ventilator transition kit XS
5/box
OJR412VT
Optiflow Junior 2 Nasal Interface Ventilator transition kit S
5/box
OJR414VT
Optiflow Junior 2 Nasal Interface Ventilator transition kit M
5/box
OJR416VT
Optiflow Junior 2 Nasal Interface Ventilator transition kit L
5/box
OJR418VT
Optiflow Junior 2 Nasal Interface Ventilator transition kit XL
5/box
OJR410B
Optiflow Junior 2 Nasal Interface Blender transition kit XS
5/box
OJR412B
Optiflow Junior 2 Nasal Interface Blender transition kit S
5/box
OJR414B
Optiflow Junior 2 Nasal Interface Blender transition kit M
5/box
OJR416B
Optiflow Junior 2 Nasal Interface Blender transition kit L
5/box
OJR418B
Optiflow Junior 2 Nasal Interface Blender transition kit XL
5/box

Wigglepads replacement

Part No
Description
Quantity
WJR110
Optiflow Junior 2 Nasal Interface Wigglepad 2 Replacement (XS, S)
2/pack (20 in each pack)
WJR112
Optiflow Junior 2 Nasal Interface Wigglepad 2 Replacement (M, L, XL)
2/pack (20 in each pack)

WigglewiNG

Part No
Description
Quantity
WJR210
WigglewiNG XS S
10/box
WJR212
WigglewiNG M L XL
10/box

Optiflow Junior 2+

Part No
Description
Quantity
OJR520
Optiflow Junior 2+ Nasal Interface XXL
10/box
WJR114
Wigglepad 2 replacement XXL
20/box
WJR214
WigglewiNG XXL
10/box

F&P Nivairo RT047

Vented mask, compatible with single-limb circuits 

  • A vented mask to help with ease of care by removing the risk of confusion around exhalation port setup.
  • RollFit™ seal adapts to different face shapes and minimizes pressure on the bridge of the nose.
  • TubeFit™ zones for placement of nasogastric or orogastric tubes.
  • ErgoFit™ with Easy Clips and breathable fabric to help with fitting and adjusting.
  • Available in four mask sizes: XS, S, M and L. 

Learn how to fit the F&P Nivairo™ mask

Watch this fitting video to learn how to size, fit, adjust and remove the mask.

Product Codes

Part No
Description
Quantity
RT047XS
Hospital, vented, full face mask, compatible with single-limb circuits; Extra Small
10/box
RT047S
Hospital, vented, full face mask, compatible with single-limb circuits; Small
10/box
RT047M
Hospital, vented, full face mask, compatible with single-limb circuits; Medium
10/box
RT047L
Hospital, vented, full face mask, compatible with single-limb circuits; Large
10/box
RT047 Specifications
Mask Type
Vented with anti-asphyxiation valve
Operating Pressures
4 - 25 cmH2O
Recommended Breathing Circuits
RT219 Bi-Level/CPAP Circuit
Product Use
Single-patient use; maximum 14 days
Materials
Silicone, Acetal, Polycarbonate, Nylon, Elastane, Polyester, Polyether Polyurethane Foam, Polyester Polyurethane Foam
Destruction
Incineration, or according to hospital protocol
Classification
Class II

F&P Nivairo RT046

Non-vented mask, compatible with dual-limb circuits

  • RollFit™ seal adapts to different face shapes and minimizes pressure on the bridge of the nose.
  • TubeFit™ zones for placement of a nasogastric or orogastric tubes.
  • ErgoFit™ with easy clips and breathable fabric to help with fitting and adjusting.
  • Available in four mask sizes: XS, S, M and L. 

Learn how to fit the F&P Nivairo™ mask

Watch this fitting video to learn how to size, fit, adjust and remove the mask.

Product Codes

Part No
Description
Quantity
RT046XS
Hospital, non-vented, full face mask, compatible with dual-limb circuits; Extra small
10/box
RT046S
Hospital, non-vented, full face mask, compatible with dual-limb circuits; Small
10/box
RT046M
Hospital, non-vented, full face mask, compatible with dual-limb circuits; Medium
10/box
RT046L
Hospital, non-vented, full face mask, compatible with dual-limb circuits; Large
10/box
RT046 Specifications
Mask Type
Non-vented with standard elbow
Operating Pressures
4 - 25 cmH2O
Recommended Breathing Circuits
RT380 or RT210/RT200
Product Use
Single-patient use; maximum 14 days
Materials
Silicone, Acetal, Polycarbonate, Nylon, Elastane, Polyester, Polyether Polyurethane Foam, Polyester Polyurethane Foam
Destruction
Incineration, or according to hospital protocol
Classification
Class II

F&P Nivairo RT045

Non-vented mask, compatible with single-limb circuits, requiring exhalation port

  • An anti-asphyxiation valve for safety in case of ventilator failure.
  • RollFit™ seal adapts to different face shapes and minimizes pressure on the bridge of the nose.
  • TubeFit™ zones for placement of nasogastric or orogastric tubes.
  • ErgoFit™ with Easy Clips and breathable fabric to help with fitting and adjusting.
  • Available in four mask sizes: XS, S, M and L.

Learn how to fit the F&P Nivairo™ mask

Watch this fitting video to learn how to size, fit, adjust and remove the mask.

Product Codes

Part No
Description
Quantity
RT045XS
Hospital, non-vented, full face mask, compatible with single-limb circuits, requiring exhalation port; Extra small
10/box
RT045S
Hospital, non-vented, full face mask, compatible with single-limb circuits, requiring exhalation port; Small
10/box
RT045M
Hospital, non-vented, full face mask, compatible with single-limb circuits, requiring exhalation port; Medium
10/box
RT045L
Hospital, non-vented, full face mask, compatible with single-limb circuits, requiring exhalation port; Large
10/box
RT045 Specifications
Mask Type
Non-vented with anti-asphyxiation valve
Operating Pressures
4 - 25 cmH2O
Recommended Breathing Circuits
RT219 Bi-Level/CPAP Circuit
Product Use
Single-patient use; maximum 14 days
Materials
Silicone, Acetal, Polycarbonate, Nylon, Elastane, Polyester, Polyether Polyurethane Foam, Polyester Polyurethane Foam
Destruction
Incineration, or according to hospital protocol
Classification
Class II

Airvo™ 2 Nasal High Flow/HFNC System [2 - 60 L/min]

Airvo™ 2 for standalone delivery of Optiflow™ nasal high flow therapy.

A device designed to facilitate the treatment of a broad patient group across hospital areas, staffed by many types of clinicians.

Designed to treat patients across the hospital

A wide flow range (2 – 60 L/min) facilitates the treatment of a broad patient group in a variety of hospital areas staffed by many types of clinicians.

Nasal high flow therapy (NHF) is recommended in several clinical applications among recently published clinical practice guidelines.

A review of the studies referenced by the clinical practice guidelines showed that the majority of the studies used flows of ≥ 45 L/min, i.e., flow rate matters.

Airvo-Optiflow system

  • Airvo 2 nasal high flow system
  • AirSpiral™ heated breathing tube & chamber kit. Airspiral kit with neb option
  • Optiflow interfaces for adult and peadiatric applications, including cannula, tracheostomy and mask adapter options
  • Hospital stand

MR810 Respiratory Humidifier

  • Three temperature and humidity settings
  • Integrated heater wire adapter
  • Ambient temperature sensor
  • Compatable with heated wire circuits

MR850 Respiratory Humidifier

One System for All Patients

The MR850 can be used for the full range of Fisher & Paykel Healthcare therapies across the F&P Respiratory Care Continuum™

  • One device supports multiple therapies for adult, pediatric and neonatal patients
  • Proven to consistently perform
  • Designed to withstand daily hospital use
  • Flow sensor technology. Automatic standby during periods of gas flow interruption
  • Condensation Control and Humidity Compensation. Automatic algorithms designed to reduce mobile circuit condensate

The MR850 can be used for the full range of Fisher & Paykel Healthcare therapies across the F&P Respiratory Care Continuum™

F&P 850 System for Optiflow™ High Flow therapy

F&P 850 System for Invasive Ventilation

F&P 850 System for Invasive Ventilation

Aerogen Pro

Discover Aerogen Pro – a multi-patient use, portable nebuliser that can be sterilised and reused for patients throughout the hospital.

Multiple Configuration Options

3 ways to configure Aerogen Pro: within a ventilator circuit, with adult and pediatric face masks, and with a mouthpiece allowing for greater flexibility in use.

Significantly Greater Deposition

Delivering significantly greater lung deposition compared to jet nebulizer’s delivery systems.

Simple & Quiet

Easy to setup and virtually silent operation, with no added flow required.

Aerogen Solo

The Aerogen Solo can support aerosol drug delivery at every stage of a patient’s respiratory journey: during invasive mechanical ventilation, non-invasive support such as non-invasive ventilation (NIV), high-flow (HF) therapies and when self-ventilating.

  • Quick and easy to set up
  • Virtually silent
  • Single patient use
  • 28 days intermittent or 7 days continuous use
  • No added flow
  • Refill medication cup without opening the circuit
  • 6 mL cup
  • Can be placed at the wye or at the humidifier

2003FF NEO2 Blend with 3.5 lpm and 15 lpm flowmeters

  • For the smallest patients where accuracy matters
  • Available with two 15 lpm flowmeters or 1 lpm and 15lpm flowmeters

2003FL Close mounted Flowmeter, 0-15lpm

  • Ideal for Labor and Delivery
  • Small and efficient foot print where space is at a premium
  • Bleed flow control on the side to ensure accuracy and avoid wasted gas

The SLE6000 Big Technology for Little Lungs

Customise your ventilator to your patient’s needs.

The SLE6000 is SLE’s most versatile ventilator. Its modular design means that you can customise it to suit your patients. Add single-tube NIV modes, HFOV, VTV, SpO2 , etCO2 and Auto O2 to suit your way of working.

Optimised for the smallest of patients.

SLE specialises in infant ventilation and as with all of our ventilators the SLE6000 is optimised for the smallest of patients. SLE6000 Infant ventilator the complete “all in one” solution for critical care, high dependency and non-invasive respiratory support, providing seamless high quality and precise controlled infant ventilation.

High spec features.

SLE6000 High Frequency Oscillation Ventilation (HFOV) – The power and waveform shape for active volume control with lower pressure and optimal frequency range for Lung protective ventilation.

SLE6000 Oxygenie® second by second Oxygen control to achieve a stable SpO2, reducing hyperoximia and hypoximia and the need for manual adjustments as part of your ventilation therapy to improve patient outcomes.